TitleProduct

Hospital Baby Care Touch Screen Infant Baby Incubator (BabyCare 2000)

  • Price:

    Negotiable

  • minimum:

  • Total supply:

  • Delivery term:

    The date of payment from buyers deliver within days

  • seat:

    Jiangsu

  • Validity to:

    Long-term effective

  • Last update:

    2017-12-27 06:57

  • Browse the number:

    214

Send an inquiries
+
Nanjing Poweam Medical Co., Ltd.
Contactaixin:

Mr. Shine(Mr.)  

Email:

telephone:

phone:

Arrea:

Jiangsu

Address:

No. 18 Fenghua Road, Yuhua Economic Development Zone, Nanjing City, Jiangsu Province, China 210000

Website:

http://poweam-medical.chinamerchants-logistics.com/

+

Two control modes: Air mode and baby mode controlled by micro-computer
The information can be stored, consulted and indicated by the LCD display screen
Humidity and oxygen concentration display and servo control
>37ºC temperature set function
Double wall hood, air circulation system in the way of air outlet from front and back
X-ray cassette under the bassinet
Embedded integrated sensor module, integrated water reservoir in the shape of drawer
Inclination of bassinet is adjustable
The height of whole unit can be adjusted
Failure alarm indication
RS-232 connector

Below is tech spec::
Power supply AC220V-230V/50Hz or AC110V-120V/50-60Hz
Max. Power output 1300VA
Mode of control Air mode and baby mode controlled by micro-computer
Air temperature control range 25ºC-37ºC (over mode 37-39ºC)
Baby temperature control range 34ºC-37ºC (over mode 37-38ºC)
Accuracy of skin temperature sensor +-0.3ºC
Temperature variability <=0.5ºC
Temperature uniformity <=0.8ºC (mattress is on the horizontal position)
Inclination of the bassinet +-8
Noide inside hood <=45dB(A) (Environment noise <=35dB(A))
Failure alarm over-temperature alarm, temperature deviation alarm, sensor alarm, motor fan failed alarm, power failure alarm, sensor box position alarm, tank position alarm, system alarm and so on
Humidity display range 0%RH~99%RH
Humidity control range 0%RH~90%RH
Accuracy of humidity +-10%RH
Indication range of oxygen concentration 0%~99%
Control range of oxygen concentration 20%~60%
Accuracy of oxygen concentration +-3%
Range of weight 100-8000g
Resolution for weight indication 1g
Accuracy of weight +-1%
Operating temperature range 20ºC~30ºC
Ambient air movement rate <0.3m/s
Standard Configuration Baby compartment, main body, vertical height adjustment stand (VHA stand), the controller, I.V. Pole and shelf
Optional Configuration Weighing system and monitor shelf, Disposable skin temperature sensor